Sign in
|
English
|
Terms of Use
Dictionary
Forum
Contacts
Arabic
Bulgarian
Chinese
Croatian
Czech
Danish
Dutch
English
Estonian
Finnish
French
German
Greek
Hungarian
Irish
Italian
Japanese
Korean
Latin
Latvian
Lithuanian
Maltese
Norwegian Bokmål
Polish
Portuguese
Romanian
Russian
Slovak
Slovene
Spanish
Swedish
Turkish
Ukrainian
⇄
Arabic
Bulgarian
Chinese
Croatian
Czech
Danish
Dutch
English
Estonian
Finnish
French
German
Greek
Hungarian
Irish
Italian
Japanese
Korean
Latin
Latvian
Lithuanian
Maltese
Norwegian Bokmål
Polish
Portuguese
Romanian
Russian
Slovak
Slovene
Spanish
Swedish
Turkish
Ukrainian
A
B
C
D
E
F
G
H
I
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Z
<<
>>
Terms for subject
Metrology
(318 entries)
primary element
The primary element of a measuring chain which converts the input variable into a signal suitable for measurement
process conditions
Specification of the allowable process conditions under which the measurement equipment can be operated within its specified accuracy limits and/or without permanent impairment of its operating characteristics
process connection
Where appropriate, the type of process connection
s
used by the measuring equipment, indicating nominal diameters, rated pressures and standards
Process Field Bus
Field bus developed by a consortium of mostly German firms and defined in German standard DIN 19 245, Parts 1-4
process pressure limits
The range of pressures to which the wetted parts of the measuring equipment may be subject without permanent impairment of operating characteristics
process pressure range
The range of pressures within which the wetted parts of the measuring equipment are designed to operate within specified accuracy limits
process temperature limits
The range of temperatures of the process medium to which the wetted parts of the measuring equipment may be subject without permanent impairment of operating characteristics
process temperature range
The range of temperatures within which the wetted parts of the measuring equipment are designed to operate within specified accuracy limits
protective cover
A cover or roof that is mounted upon the housing of an instrument to protect it against the effects of sunshine, rain, wind etc
protocol
A protocol is a set of conventions relating to the data format and control procedures necessary for communication between two devices or processes
pure water
Water with a conductivity of 0.1 uS/m to approx. 10 p.S/m at 25°C
quality certificate
Test certificate with test results based on a specific test. Corresponds to inspection certificate 3.1B with regard to content but does not include an approval by the factory expert. The quality certificate is supplied with selected products as part of the documentation without special request
quantisation
Process by which the range of a variable is divided into a finite number of distinct subranges, not necessarily equal, each of which is represented by an assigned value named the quantized value
RACKBUS®
Registered trademark of Mestra AG, Reinach, Switzerland. Proprietary bus for connecting intrinsically transmitters to controlling gateways
RACKBUS® RS-485
Proprietary bus for connecting intrinsically transmitters to controlling gateways
range
The region of the values between the upper and lower limits of the quantity under consideration - usually used with a modifier, e.g. temperature range, measuring range
RBE dose
relative biological effectiveness dose
reapproval
This is the regular check made by the weights and measures office that the instrument is still measuring correctly
reference electrode
Electrode the galvanic voltage of which can be reproducibly set without being influenced by the medium being measured
reference operating condition
The conditions under which the equipment was tested. Reference operating conditions are stipulated operating conditions for testing measurement equipment or the comparison of measured values. They are usually fixed reference values for the influence quantities which are acting upon the measurement equipment
Get short URL